AQ6150 Optical Wavelength Meter

Brand: Yokogawa Electric Corporation

The AQ6150 series optical wavelength meter is an ideal instrument for accurately measuring the optical wavelength of optical devices and systems used in telecommunication applications from 1270 to 1650 nm (Including C & L Band).

By employing a Michelson interferometer and a high speed Fast Fourier Transform (FFT) algorithm, the AQ6150 series can measure not only a single wavelength laser signal but also a multiple wavelength laser signal from a DWDM system and Fabry-Perot laser.

Furthermore, this technology enables the measurement of modulated laser signals in addition to the CW signal from an optical transceiver.

The optimized optical design and data processing routine significantly reduces the measurement time and improves manufacturing throughput.
Features
  • High wavelength accuracy of ±0.3pm
  • Cope with modulated light and optical filter measurement
  • Simultaneous measurement of up to 1024 wavelengths
  • Increase throughput with high speed measurement
  • User-friendly interface
  • Reduce the lifetime ownership cost

Specifications

Accuracy

  • ± 0.5 dB (1,550 Nm, -10 dBm) - Power Accuracy
  • ± 0.7 ppm (± 1 Pm at 1,550 Nm) - Wavelength Accuracy

Approvals & Certifications

  • AS
  • BS
  • CSA
  • EMC (Emission): EN 61326-1 Class A, EN 55011 Class A Group 1
  • EMC (Immunity): EN 61326-1 Table 2
  • EMC (Laser): IEC 60825-1 Class I,
  • NBR
  • RoHS: EN 50581
  • UL
  • VDE

Calibration

  • 1-Year - Recommended Calibration Period

Communication

  • Ethernet
  • GPIB
  • TCP/IP Protocols
  • USB
  • VGA Output

Connectors

  • Optical Connector [FC/PC or SC/PC (AQ9441 Universal Adapter)]

Display

  • 5.7” Color LCD (640x480) Pixels
  • LED Display

Electrical Connectors

  • AWG

Frequency

  • 5 GHz (40 Pm at 1,550 Nm, Equal Power Lines Input) - Min. Resolvable Separation for Wavelength

Function

  • FP-LD Analysis
  • Measurement (Single, Repeat, Average, Drift, Data Logging)

Humidity

  • 20 to 85 % Relative Humidity, Non-Condensing

Input Power

  • 10 dBm (Total of All Lines) - Max.
  • 18 dBm (Total of All Lines) - Safe, Max.
  • -30 dBm (1,600 to 1,650 Nm, Single Line Input) - Min. Input Power
  • -40 dBm (1,270 to 1,600 Nm, Single Line Input) - Min. Input Power

Linearization

  • ± 0.3 dB (1,550 Nm, -30 dBm or Higher) - Power Linearity

Measuring Time

  • 0.3 seconds or Less (Single Measurement)

Operating Temperature

  • 5° to 35° C (41° to 95° F)

Polarization

  • ± 0.5 dB (1,550 Nm) - Polarization Dependency for Power

Power Requirement

  • 100-240 Vac, 50/60 Hz, Approximately 100 VA

Resolution

  • 0.0001 Nm - Display Resolution for Wavelength
  • 0.01 dB - Display Resolution for Power

Storage Temperature

  • -10° to 50° C (14° to 122° F)

Temperature Range

  • 10° to 30° C (50° to 86° F) - Performance Guarantee Temperature

Update Time

  • 60 minutes or more - Warm-Up Time

Wavelength

  • 1,270 to 1,650 Nm
show more