ISC450G Inductive Conductivity Converter

Brand: Yokogawa Electric Corporation

The new EXAxt 450 series has been designed to meet the highest market requirements of today’s industry. 

This series of analyzers is unique as it will no longer be the uncertainty factor of your quality demands, but instead will bring you to a higher level.

The EXAxt will help you and guide you as the unique Human Machine Interface (HMI) will not only present you reliable process data, but diagnostics, trends, logbooks and step by step calibration routines to become your friend in analytical measurement and help you gaining that higher level of quality.

The instrument is easy to set up, very intuitive and can be used without the need of an Instruction Manual. 

The HMI has a clear menu structure in the language of your preference (English, French, German, Spanish, Italian, Swedish Portuguese and Japanese.) 

The touch screen interface provides access to the display features. 

The main display gives three process values at the same time.
Features
  • Unique intuitive HMI menu structure in 8 languages.
  • Process data trending up to 2 weeks.
  • Predefined OIML standard solutions.
  • Predefined matrices for precise temperature compensation.
  • Two mA-outputs and four SPDT relay contacts with display indicators.
  • %weight on display.
  • HART® Communications.
  • FM Class I, Div. 2, Group ABCD, T6 for Ta -20 to 55ºC

Specifications

Accuracy

  • ≤ 0.3° C (0.6° F) - Temperature
  • ≤ 0.5 % of Reading ± 1 µS/cm - Conductivity
  • ≤ 1 % for NaCl, ≤ 3 % for Matrix - Temperature Compensation
  • ≤ 4 seconds for 90 % (For a 2 Decadestep) - Step Response

Alarm

  • High/Low Process Alarms

Ambient Temperature Range

  • -20° to 55° C (-5° to 130° F)

Approvals & Certifications

  • CSA: C22.2 No.61010-1
  • EMC: EN 61326-1 Class A, Table 2 EN 61326-2-3 EN 61000-3-2 Class A EN 61000-3-3
  • FM: FM3611 Class I, Div. 2, Groups A, B, C, D, T6 for Ta -20° to 55° C (-4° to 131° F)
  • IEC 61010: II
  • KC
  • NAMUR NE43
  • RCM: EN 61326-1 Class A

Approvals & Certifications

  • OIML

Burn-Out

  • Burn Down (3.6 mA) to Signal Failure According to NAMUR NE43 for Transmission Signals
  • Burn Up (21 mA) to Signal Failure According to NAMUR NE43

Cable Length

  • Maximum

Capacity

  • Maximum

Communication

  • Bi-Directional HART Digital Communication, Superimposed on mA1 (4-20 mA) Signal

Compensated Temperature

  • 0° to 100° C (32° to 212° F)

Conduit Connection

  • 1/2” NPT Female
  • G 1/2” Female
  • M20 Female

Consumption

  • 10 W - Power Consumption
  • 15 VA - Power Consumption

Control Functions Characteristics

  • Adjustable Damping - Contact Outputs
  • Expire Time - Contact Outputs
  • ON/OFF
  • PID Control

Diameter

  • 0.24” to 0.47” (6 to 12 mm) - Overall Cable Diameter

Display

  • Backlight: LED & TouchScreen
  • Graphical Quarter VGA (320 x 240)
  • LCD Display

Electrical Connectors

  • 26 to 12 AWG (0.13 to 4 mm²) - Conducter Cross Section

Enclosure Finish

  • Chemically Resistant Coating
  • Colour: Silver Gray

Enclosure, Body Material

  • Polycarbonate Cover with Polycarbonate Flexible Window

Environmental Protection

  • IP66
  • NEMA 3S
  • NEMA 4X

Frequency

  • 50 Hz ± 5 % - Acceptable Range for ISC450 G-A
  • 50/60 Hz - Ratings for ISC450 G-A
  • 60 Hz ± 5 % - Acceptable Range for ISC450 G-A

Function

  • Automatic or Manual for Temperature Compensation
  • Diagnostic Functions to Increase the Dependability of the Instrument

Humidity

  • 10 to 90 % Relative Humidity at 40° C (100° F), Non-Condensing

Input

  • 0 to 1,999 ms/cm at 25° C (77° F) - Conductivity
  • Maximum
  • Minimum 1 µS/cm at Process Temperature

Input Impedance

  • 100 kiloohms: 1 x Range - Contact Open

Load

  • 600 ohms, Max.

Materials of Construction

  • CPVC Immersion Fitting
  • Polypropylene Flow Fittings
  • Polyvinylidene Fluoride Flow Fittings
  • Stainless Steel Tag Plate

Mounting

  • Bulkhead
  • Panel Mount
  • Pipe Mounting
  • Surface Mounting on a Plate
  • Universal Mounting
  • Wall Mounting on a Bracket

Mounting Position

  • Horizontal (Nominal Diameter JIS 50A) - Pipe
  • Vertical (Nominal Diameter JIS 50A) - Pipe

Output

  • Two Isolated Outputs of 4-20 mA DC with Common Negative

Output Function

  • Burn
  • Hold
  • Linear Output or 21-Step Table for Conductivity, Concentration or Temperature - Transmission Signals

PID Configuration

  • PID Duty Cycle

Power Supply

  • 10.8-26.4 Vdc - Acceptable Range for ISC450 G-D
  • 100-240 Vac - Ratings for ISC450 G-A
  • 12-24 Vdc - Ratings for ISC450 G-D
  • 90-264 Vac - Acceptable Range for ISC450 G-A

Sensor, Probe Type

  • Pt1000

Size

  • 0.8” (20 mm) - Wrench Size

Span - Maximum

  • 1,999 ms/cm - Transmission Signals

Span - Minimum

  • 10 µS/cm ≥ 10 % of High Value (20 mA)

Storage Temperature

  • -30° to 70° C (-22° to 158° F)

Switch Type

  • 4 SPDT Relay Contacts

Temperature Range

  • -20° to 140° C (-4° to 284° F)

Tolerance

  • Output Tolerance: ± 0.02 mA of 4-20 mA