PX8000 Precision Power Scope

Brand: Yokogawa Electric Corporation

The PX8000 brings together Yokogawa’s world-leading expertise in power measurement with our long heritage in oscilloscope design to deliver a true test and measurement revolution: the world’s first precision power scope. 

With the launch of the PX8000, R&D professionals need no longer compromise on their need for high-accuracy time-based power measurement, a need that conventional power analyzers and oscilloscopes were never designed to meet. 

As more and more innovation focuses on energy consumption and the integration of electronics into power-based systems, so more and more engineers are demanding accuracy and precision from their power measurement.
Features
  • Insight - Precision power measurement gives true insights into energy consumption and performance
  • Confidence - Proven, high-quality production means the PX8000 can be relied upon to deliver over extended periods of time
  • Familiarity - Users experience a short learning curve thanks to features familiar to anyone who’s used to power measurements or oscilloscopes

Specifications

Accuracy

  • ± (0.05 % of Reading) ± 1 Count Error (10 Nanoseconds) - the Observation Time is Greater or Equal to 300 times the Period of the Pulse
  • ± (0.1 % of Reading + 0.1 % of Range), 45 Hz to 1 kHz
  • ± (1.5 % of Reading + 0.6 % of Range)
  • ± 0.1 % of Reading
  • DC: ± 1 % of Range Typical - Analog

Approvals & Certifications

  • AS
  • BS
  • CSA
  • NBR
  • UL
  • VDE

Bandwidth

  • DC to 10 MHz
  • DC to 20 MHz

Channels

  • 2-Channels, Switchable Analog or Pulse Input - Auxiliary (AUX) Module
  • 8-Channels, Combination of Voltage/Current Modules & AUX Module

Communication

  • Ethernet (1,000Base-T, 100Base-TX or 10Base-T) - Transmission System
  • GPIB
  • IRIG
  • TCP/IP Protocols - Ethernet
  • USB - Ports for Peripherals & Peripheral Interface

Display

  • 1,024 x 768 x GA - Dots
  • 10.4-Inch TFT Color LCD Display
  • 5-Digits (Displaying 99,999) - Max.
  • 6-Digit (999,999) - Max.
  • 801 x 656 (Waveform Display) - Waveform Displaying Dot Size
  • Bar Graph Display - the Amplitude of Each Harmonics when It is Harmonic Measurement
  • Vector Display - Display the Phase Angle between the Fundamental Voltage Signal & Fundamental Current Signal as a Vector

Electrical Connectors

  • BNC Connector - Input/Output EXT TRIG IN, OUT, CLK IN, Time Sync Signal Input
  • D-Sub 15-Pin Receptacle - Video Output
  • GP-IB: 24-Pin Connector
  • Plug-In Input Module Style - Shape: Input
  • Plug-In Terminal (Female for Voltage, Male for Current) - Input Terminal Typical
  • RJ45 Modular Jack - Ethernet
  • USB Typical B Receptacle

Frequency

  • 1.8 Hz to 2 MHz - Displaying Range: Frequency Measurement Range
  • 100 Hz to 20 kHz (Same as Zero-Cross Filter) - Measurement Filter, Frequency Filter
  • 2 Hz to 1 MHz - Frequency Measurement Range
  • 20 Hz to 409.6 kHz - Fundamental Frequency of the PLL Source
  • 5 MHz, Max.
  • 50/60 Hz - Rated Supply
  • 500 Hz to 1 MHz - Line Filter
  • DC to 20 MHz (-3 dB Point when Sine Wave of Amplitude ± 3 Division is Applied)

Humidity

  • 20 to 80 % Relative Humidity - Ambient

Input

  • 1.5 V-1,000 Vrms - Direct Input (Voltage Module)
  • 10 mA-5 Arms
  • 50 mV-10 Vrms - Sensor Input
  • AC & DC, or GND - Input Coupling
  • Current: Floating Input through Shunt - Input Format
  • Input Level: TTL - Input/Output EXT TRIG IN, CLK IN
  • Isolated Unbalanced - Input Format (Auniliary (AUX) Module)
  • Maximum
  • Two Input Channels, Switchable Analog or Pulse Input
  • Up to 1,000 V (DC + ACpeak) Via Probe Input - Auxiliary (AUX) Module
  • Up to 200 V (DC + ACpeak) Via Direct Input - Auxiliary (AUX) Module
  • Voltage: Floating Input, Resistive Voltage Divider - Input Format

Input Impedance

  • 50 to 5,000 ohms

Insulation Resistance

  • 10 megaohms or more at 500 Vdc between the Power Supply & Case

Measuring Range

  • 1.5 / 3 / 6 / 10 / 15 / 30 / 60 / 100 / 150 / 300 / 600 / 1,000 Vrms - Voltage (Crest Factor=2 at Rated Range Input)
  • 10 m / 20 m / 50 m / 100 m / 200 m / 500 m / 1/2 / 5 Arms - Direct Current Input (5 A) (Crest Factor=2 at Rated Range Input)
  • 50 m / 100 m / 200 m / 500 m / 1/2 / 5 / 10 Vrms (Crest Factor = 2) - Current: External Current Sensor Input (760812)

Output

  • ± 12 Vdc - Probe Power Output
  • ± 15 V - Sensor Power Output
  • 5 V CMOS - EXT TRG OUT Output Level
  • Probe & Sensor Power Output: Total, Max.

Output Format

  • Analog RGB Output - Video Output

Pulse Range

  • 100 Nanoseconds - Min. Pulse Width: Input/Output EXT TRIG IN
  • 50 Nanoseconds - Min. Pulse Width: EXT CLK IN
  • 500 Nanoseconds or Wider: Pulse Width

Resolution

  • 12-bits - A/D Converter
  • XGA-Compliant Output 1,024 x 768 Dots (Approximately 60 Hz Vsync (Dot Clock Frequency: 66 MHz))

Supply Voltage

  • 1,500 Vac for One Minute between the Power Supply & Case
  • 100-120 Vac
  • 220-240 Vac (Auto Switching)
  • Voltage-Axis Sensitivity Setting: 50 mV-100 V

Temperature Coefficient

  • ± (0.1 % of Range)/°C Typical

Update Time

  • 30 minutes

Wiring

  • 2-Wire: (Single-Phase) 1P2W
  • 3-Wire: (Single-Phase) 1P3W, (3-Phase) 3P3W, (3-Phase, 3 Power Metal Method) 3V3A
  • 4-Wire: (3-Phase) 3P4W