DM7560 Digital Multimeter

Brand: Yokogawa Electric Corporation

The DM7560 is a flexible 6.5-digit digital multimeter with high-accuracy, high-speed data logging (up to 30 kS/s) with deep 100 k reading memory and built-in statistical analysis.
Features
  • High resolution up to 6-1/2 digits
  • Full-color, high-resolution display with flexible display formats
  • High-speed data logging with up to 30 k points per second
  • High-capacity internal memory up to 100 k points
  • Trend/histogram analysis available both in real-time and offline
  • Multiple PC interface options (USB, Ethernet, GP-IB, RS-232) enable automation

Specifications

Accuracy

  • ± (0.0050 % of Reading + 0.0035 % of Range) - DC Voltage
  • ± (0.010 % of Reading + 0.020 % of Range) - Continuity & Diode Test
  • ± (0.120 % of Reading + 0.020 % of Range) - DC Current
  • ± (0.20 % of Reading + 0.70° C (1.26° F)) - Thermocouple
  • ± (0.70 % of Reading + 0.04 % of Range) - AC Current
  • ± (0.800 % of Reading + 0.010 % of Range) - Terminal Resistance
  • ± (4 % of Reading + 0.50 % of Range) - AC Voltage
  • ± 0.06° C (± 0.1° F) - RTD
  • 0.1 % of Reading - Frequency

Applications

  • Monitoring Battery Current Consumption
  • Production Test
  • Research Institutions R&D/Service
  • Testing Sensor
  • Voltage Reference Testing

Approvals & Certifications

  • AS
  • BS
  • CSA
  • GB
  • NBR
  • PSE
  • UL
  • VDE

Communication

  • Bit Rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 bit/sec
  • LAN Setting: DHCP (ON/OFF), IP Address, Gateway, Subnet Mask
  • RS-232
  • Stop Bit: 1-bit, 2-bits
  • USB

Consumption

  • 21 VA or Less - Power Consumption

Current

  • 500 NA -1 mA - Terminal Resistance

Delay Time

  • < 1 μs - Trigger Input (BNC)
  • 0 to 3,600 seconds Setting Range - Trigger Delay & Interval

Display

  • 4.3” (109 mm): TFT Active Matrix
  • 5-1/2” Digits
  • 6-1/2” Digits
  • Backlight: LED
  • LCD Display
  • Sampling Method: 2.5 to 30 K S/s (DC Function), 2.5 to 5 S/s (AC Filter), 100 S/s (Continuity & Diode Test)

Frequency

  • 20 Hz to 300 kHz - AC Voltage
  • 20 Hz to 5 kHz - AC Current
  • 3 Hz to 300 kHz (Gate Time: 1 millisecond to 1 second)
  • 50/60 Hz - Power Frequency

Humidity

  • 80 % Relative Humidity (No Dew Allowed Below the Moisture Amount) - Calculation Guaranteed Temperature
  • 90 % Relative Humidity (No Dew Allowed Below the Moisture Amount) - Storage Temperature

Input

  • 0.6 V Max.
  • 0.9 V Max.
  • 1 mA-3 A - DC Current
  • 100 mV-1,000 V - DC Voltage
  • 100 mV-750 V - AC Voltage
  • 1-3 mA - AC Current
  • 2.4 V Min. - Trigger Input (BNC), Trigger Inhibit Input (DIO Option)

Input Impedance

  • 0.1 ohms - AC Current
  • 0.1 to 90 ohms - DC Current
  • 1 GigaOhms or more or 10 megaohms ± 1 % for 0.1-10 V Range - DC Voltage
  • 1 Megaohm / 100 PF or Less Approximately - AC Voltage
  • 10 kiloohms - Trigger Input (BNC)
  • 10 megaohms ± 1 % for 100-1,000 V Range - DC Voltage
  • 5 kiloohms - Trigger Inhibit Input (DIO Option)

Input Signal

  • AC & DC Current
  • AC & DC Voltage

Interface Connection

  • DIO Interface
  • GPIB

Maximum Current

  • 100 mA - Max.
  • 3 A (Continuous, Protection by 3 A Fuse) - Max.

Maximum Voltage

  • 1,100 Vpeak (1 Minute) - Max.
  • 750 Vrms or ± 500 V or Less, Max.
  • 800 Vpeak (Continuous) - Max.

Output

  • 0.4 Vmaximum - Complete Output (BNC)
  • 2.4 Vminimum - Complete Output (BNC)

Output Impedence

  • 1 Kiloohm - COMPLETE Output (BNC)

Output Noise

  • 120 Db at 50/60 Hz, ± 0.1 % for CMRR - Noise Rejection in Multiple of 1 PLC
  • 55 dB at 50/60 Hz, ± 0.1 % for NMRR - Noise Rejection in Multiple of 1 PLC

Power Supply

  • 100 Vac
  • 115 Vac
  • 220 Vac
  • 240 Vac ± 10 %
  • 50/60 Hz

Pulse Range

  • 1 microsecond or more - Trigger Input (BNC)
  • 10 µs at Limit Judgment Off - Output Pulse Width (BNC)
  • 4 milliseconds or more at Limit Judgment ON - Output Pulse Width (BNC)

Resistance

  • 1 Kiloohm - Continuity Test
  • 100 ohms to 100 megaohms - 2 (2 W ohms) & 4 (4 W ohms) Terminal Resistance

Resolution

  • 0.001° C - Thermocouple
  • 0.01° C - RTD
  • 1 mV - AC & DC Voltage
  • 1 % - Bulk Mode
  • 10 µs - Trigger Function
  • 10 milliohms - Continuity Test
  • 10 μA - AC & DC Current
  • 100 ohms - Terminal Resistance

Response Time

  • Within 1 second - DC Voltage
  • Within 2 seconds - AC Filter (HIGH)
  • Within 3 seconds - AC Filter (MID)

RTD Type

  • JPt100
  • Pt100

Sensor, Probe Type

  • E Thermocouple (CRC)
  • J Thermocouple (IC)
  • K Thermocouple (CA)
  • RTD
  • R Thermocouple
  • T Thermocouple (CC)

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

Supply Voltage

  • ± 500 Vdc - Withstand Voltage (Between LO Terminal & Ground)
  • 42 Vpeak - Limit Judge Output (DIO Option)

Temperature Coefficient

  • ± (0.001 % of Reading + 0.002 % of Range)/°C - Continuity & Diode Test
  • ± (0.0050 % of Reading + 0.0005 % of Range)/°C - DC Voltage
  • ± (0.100 % of Reading + 0.006 % of Range)/°C - AC Current
  • ± (0.200 % of Reading + 0.020 % of Range)/°C - AC Voltage
  • ± 0.003° C/°C - RTD

Temperature Range

  • 0° to 50° C (32° to 122° F) - Calculation Guaranteed Temperature
  • -200° to 1,765° C (-328° to 3,209° F) - Thermocouple
  • -200° to 850° C (-328° to 1,562° F) - RTD

Update Time

  • 1-Hour after Power On - Warm-Up Time
show more