Rotamass 3 Remote Rack Converter RCCR31
Brand: Yokogawa Electric CorporationROTAMASS is a Coriolis mass flowmeter with highly refined digital signal processing electronics, so that accurate and stable mass flow measurement is achieved.
ROTAMASS employs a flame-proof type converter case suitable for use in the hazardous area together with it’s intrinsically safety type detector.
ROTAMASS's signal processing, housing protection and its detector's special decoupling system against external loads and vibrations, realize high performance in real applications.
Features- ROTAMASS is a flowmeter for nearly all fluids, including high viscosity liquids, slurries and multi- phase media with a certain gas content
- Field-mount and rack-mount remote converter available
- Refined digital signal processing enables accurate and stable measurement
- A special detector decoupling system makes the device highly independent from external loads or vibrations.
- Simple flow path means self-draining, simple cleaning and suitable for use in hygenic industries.
- High accuracy and high stability over a wide flow range
- Accurate density measurement, up to +/- 0.0005 g/cm³
- Concentration measurement for solutions, suspensions and emulsions (e.g. water cut, net oil computing)
- Volume flow with reference density
- Temperature measurement
- Two analog outputs, two pulse outputs or status-out and one status-in as standard I/O
- Available in explosion proof versions (ATEX, FM, IECEx, EAC, INMETRO, NEPSI, KOSHA)
- European MID approval acc. OIML R-117-1 and American NTEP approval for Custody Transfer Measurement (see GS 01R04B07-00E-E)
- Wide process temperature range –200° to 350° C
- Microprocessor-based multifunction capability
- EEPROM protects parameter settings and totalized values during power failure.
- High visibly LCD display
- HART® communication function is available.
- Optional Foundation™ Fieldbus communication is available. (see GS 01R04B05-00E-E)
- Optional MODBUS® communication is available.
- Optional intrinsically safe outputs are available.
- Various choice of tubes materials
- EN, ASME or JIS flanges as standard, others on request
- FMEDA report on request, SIL 2, SIL 3 levels can be achieved if redundant meters are used.
Specifications
Ambient Temperature Range
- -40° to 55° C (-40° to 131° F)
Approvals & Certifications
- American NTEP Approval 12-080A2 for Custody Transfer Measurement
- ATEX: KEMA 02-ATEX-2183 x & KEMA 01-ATEX-1075 X, Flameproof & Intrinsically Safe
- EAC: Flameproof & Intrinsically Safe
- EHEDG
- EMC: EN 61326-1: 2006, Class A, EN 61326-2-3: 2006, EN 61000-3-2: 2006 & EN 61000-3-3: 2008
- European MID Approval According to OIML R-117-1 (Fluids other than Water)
- FM: Intrinsically Safe & Housing Explosion-proof
- GOST
- IEC Ex: KEM 06.0031X, Intrinsically Safe, Flameproof
- INMETRO: Flameproof & Intrinsically Safe
- KOSHA
- NAMUR: EN 60947-5-6
- NEPSI: Flameproof & Intrinsically Safe
- PED 97/23/EC
Approvals & Certifications
- Compliance According to EN 10204: 2004-2.1
- SIL 2, SIL 3 (FMEDA Report)
- Test Report According to EN 10204: 2004-2.2 (QIC)
Communication
- Baud Rate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bit/sec
- FOUNDATION Fieldbus
- HART
- Modbus ASCII/RTU
- Modbus Via RS-485 as 2-Wire Data Bus According to EIA/TIA-485
Consumption
- 10 W, Max.
- 25 VA, Max.
Damping Adjustment
- 0 to 200 seconds
Display
- LCD Display
Electrical Protection
- Lightning Protection - Arresters 2,000 A are Inside of the Converter for Power Supply Lines
Electrical Rating
- 5 A at 250 V - External Circuit Breaker Rating
Enclosure, Body Material
- Aluminum
Environmental Protection
- Explosion-proof
- Flameproof
- Intrinsically Safe
- IP20
Frequency
- 20 to 10,000 Hz - Frequency Output 1
- 20 to 2,000 Hz - Frequency Output 2
Humidity
- 0 to 95 % Relative Humidity - Ambient Humidity Range
Materials of Construction
- 304 Stainless Steel / 1.4301 - Name Plate, Mounting Bracket
Mounting
- 19” Rack-Mounted
Operating Temperature - Display
- -20° to 55° C (-4° to 131° F)
Operating Temperature - Electronics
- -40° to 55° C (-40° to 131° F)
Output
- 30 Vdc / 200 mA - Passive Transistor Contact Output, According EN 60947-5-6
- 4-20 mA DC, Galvanically Separated from Other Signals
- Active Output, 12 V, 6 mA, Resistance > 10 kiloohms
Power
- 2 A, T, Breaking Capacity 1,500 A - Fuse on Base Board (AC & DC-Typical)
Power Supply
- 24 Vdc
- 90-264 Vac
Pulse Range
- 0 to 10,000 Pulses/second - Output 1
- 0 to 2,000 Pulses/second - Output 2
Resistance
- 100 kiloohms - Status Input (Open)
- > 100 megaohms / 500 Vdc between Power & Ground Terminal (Isolation Resistance of Converter)
- > 20 megaohms / 100 Vdc between Power & I/O Terminals, I/O Terminals & Ground (Isolation Resistance of Converter)
- 20 to 600 ohms - Load Resistance (I/O Signal)
Supply Voltage
- 1,500 Vac for 1 Minute between Power & Ground Terminal (Dielectric Strength)
- 10.5-30 Vdc (without HART), 165 mA
- 16.75-30 Vdc (with HART), 165 mA
Temperature Effect
- < 0.05 % of Span Per 10° C (18° F) - Ambient Temperature Effect (I/O Signal)