YTMX580 Wireless Temperature Transmitter

Brand: Yokogawa Electric Corporation

YTMX580 can accept inputs from up to 8 points of measurement such as thermocouples (8 types: K, E, J, etc.) or RTD signals (3 types: Pt100, etc.), converting the corresponding measurement input values to a wireless signal.

It can also accept DC voltage, resistance, and 4 to 20 mA DC signal input.
Features
  • Easy Setup: Field Wireless
    • Cut back on troublesome wiring, reducing setup costs.
    • Traditional wired connections can easily be switched to a wireless solution.
  • ISA100.11a International Wireless Communication Standard
    • Advanced encryption maintains communication security.
    • Multi-vendor communication supports transmitters from a variety of manufacturers.
  • Reliable, Fast, 8-ch Multipoint Measurements
    • 8 ch universal input: Perfect for multipoint measurement applications.
    • High performance measurements with intervals as fast as 1 sec (3 ch), or 2 sec (8 ch).
    • Superb environmental tolerance:
      • Operating temperature of -40 to 85°C (-40 to 185°F).
      • Protection level of IP66/IP67 & NEMA 4X.
  • Explosion protection
    • FM, CSA: Intrinsically safe Approval, non-incendive (Class I) Approval
    • ATEX, IECEx: Intrinsically safe Approval
    • TIIS: Intrinsically safe Approval
  • Easy Battery Maintenance
    • Typical battery life is 6 years (measuring at 60 seconds intervals).
    • Battery packs can be swapped even in hazardous areas.
  • Supporting Plant Wide Field Wireless
    • Full Redundancy (Duplicate, Duocast)
    • 4hops
    • Remote Antenna + Extension cable

Specifications

Accuracy

  • ± 0.5° C (± 0.9° F) - Thermocouple for Cold Junction

Ambient Temperature Range

  • -40° to 85° C (-40° to 185° F)
  • -50° to 70° C (-58° to 158° F)

Approvals & Certifications

  • ATEX Intrinsically Safe
  • CE ETSI EN 300 328, ETSI EN 301 489-1, ETSI EN 301 489-17, EN 60950-1, EN 62311
  • CSA Intrinsically Safe, Non-Incendive
  • EMC EN 61326-1 Class A, EN 61326-2-3, EN 301 489-1, EN 301489-17
  • Ex ia IIC T4
  • FCC
  • FM Intrinsically Safe, Non-Incendive
  • IC
  • IECEx Intrinsically Safe
  • RCM: AS/NZS 4268, AS/NZS 2772.2, EN 61326-1 Class A
  • TIIS Intrinsically Safe
  • UL 61010-1, 61010-2-030

Approvals & Certifications

  • R & TTE Directive

Battery Life

  • 6 Years at 60 seconds - Update Time

Burn-Out

  • Downscale
  • Upscale

Channels

  • 8-Points

Communication

  • Data Rate: 250 Kbps - Wireless Specification
  • Data Rate: 9,600 bit/sec - Infrared Communication
  • Wireless Communication Protocol: ISA100.11a

Current

  • 5 mA or Less - Leakage Current

Diagnostics

  • Amplifier Failure
  • Battery Alarm
  • Configuration Error
  • Sensor Failure
  • Wireless Communication Alarm & Over-Range Error for Process Variables

Diameter

  • 0.437” (11.1 mm) - Outside Diameter of Cable/Sheath

Display

  • Red LEDs

Distance

  • 30 cm - Infrared Communication

Electrical Connectors

  • 1/2” NPT Female
  • 4 mm Screw Terminal
  • G 1/2” Female
  • M20 Female

Enclosure Finish

  • Epoxy Resin Coating - Base Coating
  • High Anti-Corrosion Coating
  • Polyurethane Coating - Finish Coating
  • Polyurethane Paint, Mint Green Paint (Munsell 5.6 BG 3.3/2.9 or its Equivalent)

Environmental Protection

  • IP66
  • IP67
  • NEMA 4X

Frequency

  • 2,400 to 2,483.5 MHz

Humidity

  • 0 to 100 % Relative Humidity

Indication

  • Green LED - RDY
  • Red LED - ALM

Input

  • ± 2.5 Vdc - Max.
  • 2-Wire RTD
  • 3-Wire RTD
  • 4-Wire RTD

Insulation Resistance

  • 100 megaohms or Greater at 500 Vdc

Load Impedance

  • 1 Kiloohm for T/C, mV
  • 10 ohms Per Wire for RTD, ohm

Materials of Construction

  • 316 Stainless Steel - Name Plate, Tag, Mounting Blacket

Mounting

  • 2” Pipe Mounting Bracket
  • Pipe Mounting
  • Wall Mounted

Operating Temperature

  • -40° to 85° C (-40° to 185° F)

Output

  • 4-20 mA
  • Wireless (ISA100.11a Protocol) 2.4 GHz Signal

Power

  • Maximum

Power Requirement

  • 2 x Primary Lithium-Thionyl Chloride Batteries
  • Io - 130.1 mA
  • Po - 191.2 mW

Resistance

  • 1 Kiloohm or Lower - Input Signal Source (For Thermocouple, mV)
  • 10 ohms Wire or Lower - Input Lead Wire (For RTD, ohms)
  • Input Resistance: 10 megaohms or more

RTD Type

  • Pt100
  • Pt200
  • Pt500

Sensor Input

  • Uo - 5.88 V

Sensor, Probe Type

  • B Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • N Thermocouple
  • RTD
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Supply Voltage

  • 200 Vac (50/60 Hz)
  • 330 V - Transient Overvoltage
  • 500 Vac (50/60 Hz)

Temperature Range

  • -200° to 1,820° C (-328° to 3,308° F) - Thermocouple
  • -200° to 850° C (-328° to 1,562° F) - RTD
  • -40° to 85° C (-40° to 185° F)

Tolerance

  • 3 % (For Dimentions less than 10 mm, the Tolerance is 0.3 mm)

Update Time

  • 1 to 3,600 seconds Selectable (Min. of 2 seconds with 4 or more Measuring points)

Vibration

  • 3 G or Less, at Resonant Frequencies from 10 to 2000 Hz (IEC 60770-1)
show more