EJX110B Wireless Pressure Transmitter

Brand: Yokogawa Electric Corporation

The High performance differential pressure and pressure transmitters EJX110B feature single crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam flow as well as liquid level, density, and pressure.

These transmitters transmit not only process variables but also the setting parameters using wireless signal.

The transmitters run on internal batteries, and the installation cost can be decreased since hard-wiring is not required.

The communication is compliant with ISA100.11a protocol specifications.
Features
Long Life Battery Design
Ultra low current consumption design using two high capacity lithium-thionyl chloride batteries provide wireless operation for years.

Security Assured Wireless Network Joining
Infrared communication between the devices for wireless network configuration and parameter setting.

Quick Update Time
Selectable from 0.5 second to 60 minutes for measured process value to publish wirelessly.

Specifications

Accuracy

  • ± (0.002 + 0.0019 URL/Span) % of Span
  • ± (0.005 + 0.00125 URL/Span) % of Span
  • ± (0.005 + 0.0049 URL/Span) % of Span
  • ± (0.015 + 0.01 URL/Span) % of Span
  • ± 0.04 % of Span - Reference Accuracy
  • 1 MPa or Higher: ± 0.2 % of Span

Ambient Temperature Range

  • -30° to 80° C (-22° to 176° F) LCD Visible Range
  • -40° to 85° C (-40° to 185° F)

Approvals & Certifications

  • Leak Test
  • Material Certificate
  • Pressure Test
  • R & TTE Directive

Approvals & Certifications

  • ATEX Intrinsically Safe
  • CE Category III, Module H
  • CSA Intrinsically Safe
  • EMC EN 61326-1 Class A, EN 61326-2-3
  • FCC
  • FM Intrinsically Safe
  • IC
  • IEC Ex Intrinsically Safe
  • PED 97/23/EC, 2014/68/EU

Battery Life

  • 10-Years at 60 seconds Update Time
  • 4-Years at 10 seconds Update Time

BSP Connection

  • 1/2” BSPT Female
  • 1/4” BSPT Female

Burst Pressure

  • psi: 10,000 (kPa: 68,950, bar: 689)
  • psi: 6,800 (kPa: 46,880, bar: 468)

Communication

  • Infrared Wireless Communication
  • ISA 100.11a

Diagnostics

  • Amplifier Failure
  • Battery Alarm
  • Capsule Failure
  • Configuration Error
  • Over-Range Error for Process Variables
  • Wireless Communication Alarm

Diaphragm Material

  • Hastelloy C-276

Display

  • 5-Digit Numerical Display
  • 6-Digit Unit Display
  • Bar Graph
  • LCD Display

Drain, Vent Valves & Plug

  • 316 Stainless Steel
  • Hastelloy C-276
  • Monel

Enclosure Finish

  • Anti-Corrosion Coating
  • Mint Green Paint (Munsell 5.6BG 3.3/2.9 or its Equivalent)

Environmental Protection

  • Hazardous Area
  • Intrinsically Safe
  • IP66
  • IP67
  • NEMA 4X
  • Non-Incendive

Fill Material

  • Fluorinated Oil
  • Silicone

Flange Material

  • ASTM CF-8M - Cover Flange
  • Hastelloy C-276 - Cover Flange
  • Monel - Cover Flange

Fluid

  • Gas
  • Liquid

Frequency

  • 2,400 to 2,483.5 MHz - License Free ISM Band

Gasket Material

  • Fluorinated Rubber
  • Teflon (PTFE)
  • Teflon Coated 316L Stainless Steel

Humidity

  • 0 to 100 % Relative Humidity - Ambient Humidity

Materials of Construction

  • 304 Stainless Steel - Mounting Bracket
  • 316 Stainless Steel - Name Plate & Tag

Media

  • Gas
  • Liquids
  • Steam Flow

Mounting

  • 2” Pipe Mounting Bracket

Mounting Position

  • Horizontal
  • Vertical

Mounting Position Effect

  • Tilting up to 90° will cause Zero Shift up to 0.4 kPa

NACE & NIST

  • NACE MR-0103

NPT Connection

  • 1/2” NPT Female
  • 1/4” NPT Female

Nut & Bolt Material

  • 316L Stainless Steel
  • 660 Stainless Steel
  • B7 Carbon Steel

O-Ring Material

  • Buna-N - Cover O-Ring

Operating Temperature

  • -20° to 80° C (-4° to 176° F)

Output

  • Wireless (ISA100.11a Protocol) 2.4 GHz Signal

Output Function

  • Linear & Square Root

Overpressure Effect

  • ± 0.03 % of URL - for M, H, & V Capsules

Power Requirement

  • 7.2 V, 19 Ah Lithium Thionyl Chloride Batteries

Pressure Range

  • bar: -5 to 140
  • Inches WC: -2,000 to 2,000
  • kPa: -500 to 14,000
  • psi: -72.52 to 2,031

Pressure Type

  • Absolute
  • Differential
  • Gauge

Process Connection Material

  • ASTM CF-8M
  • Hastelloy C-276
  • Monel

Process Temperature

  • -40° to 100° C (-40° to 212° F)
  • -40° to 120° C (-40° to 248° F)

Response Time

  • 150 milliseconds
  • 210 milliseconds

Stability

  • ± 0.1 % of URL Per 10-Years - for M, H, & V Capsules

Static Pressure Effect

  • ± 0.02 % of URL Per psi: 1,000 (MPa: 6.9, bar: 69) for M Capsule - Effect on Zero
  • ± 0.028 % of URL Per psi: 1,000 (MPa: 6.9, bar: 69) for H, V Capsule - Effect on Zero
  • ± 0.075 % of Span Per psi: 1,000 (MPa: 6.9, bar: 69) for F, M, H & V Capsules - Span Effects
  • ± 0.1 % of URL of Span Per psi: 1,000 (MPa: 6.9, bar: 69) for F Capsule - Effect on Zero

Supply Pressure - Maximum

  • psi: 2,300 (MPa: 16, bar: 160) - Capsule F, L
  • psi: 3,600 (MPa: 25, bar: 250) - Capsule M, H, V

Temperature Effect

  • ± (0.055 % of Span + 0.18 % of URL) Per 28° C (50° F) for Capsule F - Ambient Temperature Effects
  • ± 0.04 % of Span + 0.009 % of URL Per 28° C (50° F) for Capsule M - Ambient Temperature Effects
  • ± 0.04 % of Span + 0.0125 % of URL Per 28° C (50° F) for Capsule H, V - Ambient Temperature Effects

Update Time

  • 0.5 to 3,600 seconds - Intermittent Measurement Mode
  • 100 milliseconds - Continuous Measurement Mode

Vibration Effect

  • < 0.1 % of URL Per IEC 60770-1 Field or Pipeline with Low Vibration Level (10-60 Hz, 0.21 mm Displacement / 60 to 2,000 Hz 3 G)

Wetted Materials

  • 316 Stainless Steel
  • 316L Stainless Steel
  • Hastelloy C-276
  • Monel
  • Tantalum

Zero Offset

  • 0.01 % Incremental Resolution of Span - External Zero Adjustment
show more