EJX115A Low Flow Transmitter
Brand: Yokogawa Electric CorporationThe low flow transmitter EJX115A is a differential pressure transmitter assembled with an integral orifice and excellent for very low flow measurement. It outputs a 4-20 mA DC signal corresponding to the measured flow.
Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications.
Other key features include quick response, remote set-up using communications, diagnostics and optional status output for pressure high/low alarm.
The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available.
All EJX series models in their standard configuration, with the exception of the Fieldbus and PROFIBUS types, are certified by TÜV as complying with SIL 2 for safety requirement.
Features- Accurately: ±0.04% Square Root Output Accuracy
- Quickly: 90 ms Response Time
- Reliably: ±0.1% per 15 years Stability (DP)
Specifications
Accuracy
- ± (0.002 + 0.0019 URL/Span) % of Span (Includes Terminal-based Linearity, Hysteresis, & Repeatability) - for M Capsule
- ± (0.005 + 0.0049 URL/Span) % of Span (Includes Terminal-based Linearity, Hysteresis, & Repeatability) - for H Capsule
- ± (0.015 + 0.01 URL/Span) % of Span (Includes Terminal-based Linearity, Hysteresis, & Repeatability) - for F Capsule
- ± 0.04 % of Span (Includes Terminal-based Linearity, Hysteresis, & Repeatability) - for F, M & H Capsule
Adjustment Type
- External Zero Adjustment Screw
- Push Button
Alarm
- Down-Scale: -5 %, 3.2 mA DC or Less
- Up-Scale: 110 %, 21.6 mA DC or more
Ambient Temperature Range
- -30° to 80° C (-22° to 176° F) with LCD Display
- -40° to 85° C (-40° to 185° F)
Approvals & Certifications
- Leak Test
- Material Certificate
- Pressure Test
- SIL 2 Capability for Single Transmitter Use, SIL 3 Capability for Dual Transmitter Use, IEC 61508: 2000
- TÜV (Technischer Uberwachungsverein)
Approvals & Certifications
- ATEX Flameproof & Intrinsically Safe
- CSA Explosion-proof & Intrinsically Safe
- EMC EN 61326-1 Class A, EN 61326-2-3, EN 61326-2-5 (For Fieldbus)
- FM Explosion-proof & Intrinsically Safe
- IECEx Intrinsically Safe & Flameproof
- NAMUR NE43
- PED 2014/68/EU, 97/23/EC
BSP Connection
- 1/2” BSPT Female
Burst Pressure
- psi: 10,000 (MPa: 69, bar: 690) - for Measurement Span (Capsule) M & H
- psi: 6,800 (MPa: 47, bar: 470) - for Measurement Span (Capsule) F
Cable Material
- Polyethylene Insulated PVC Sheathed
Communication
- BRAIN
- FOUNDATION Fieldbus
- HART
- PROFIBUS PA
Current
- 6,000 A - Max.
Damping Adjustment
- 0 to 100 seconds
Dead Time
- 45 milliseconds (Nominal)
Diagnostics
- Configuration Error - Self Diagnostics
- CPU Failure - Self Diagnostics
- Hardware Failure - Self Diagnostics
- Heat Trace Monitoring - Advanced Diagnostics
- Impulse Line Blockage Detection - Advanced Diagnostics
- Over-Range Error for Differential Pressure, Satic Pressure & Capsule Temperature - Self Diagnostics
Diaphragm Material
- Hastelloy C-276 - Capsule Diaphragm
Differential Pressure
- psi: 0 to 30.46 (kPa: 0 to 210, bar: 0 to 2.1)
Display
- 10-Segment - User Configurable, Signal Characterizer
- 5-Digit Numerical Display
- 6-Digit Unit Display
- Bar Graph
- LCD Display
Distance
- 0 to 2 Kilometers (1.25 Miles) - Communication Distance
Drain, Vent Valves & Plug
- 316 Stainless Steel
Electrical Connectors
- 1/2” NPT Female
- G 1/2” Female
- M20 Female
Electrical Protection
- Lightning Protection
Electrical Rating
- 10.5-30 Vdc, 120 mA DC, Max.
Enclosure Finish
- Anti-Corrosion Coating
- Polyurethane Mint Green Paint (Munsell 5.6BG 3.3/2.9 or its Equivalent)
Enclosure, Body Material
- Aluminum Alloy - Copper Cast
- ASTM CF-8M Stainless Steel
Environmental Protection
- IP66
- IP67
- NEMA 4X
Fill Material
- Fluorinated Oil - Fill Fluid
- Silicone - Fill Fluid
Flange Material
- ASTM CF-8M - Cover Flange
Flow Rate
- 0.004 to 1.32 gpm (0.016 to 5 LPM) to Water
- 0.005 to 6.076 gpm (0.022 to 23 LPM) to Water
- 0.02 to 8.72 gpm (0.07 to 33 LPM) to Water
- 0.44 to 140 NL/min to Air - for Capsule F
- 0.63 to 635 Nl/min to Air - for Capsule M
- 2 to 910 Nl/min to Air - for Capsule H
Function
- Linear
- Square Root Programmable
Gasket Material
- Fluorinated Rubber - Process Connector Gasket
- PTFE - Orifice Gasket
- PTFE Teflon - Process Connector Gasket
- Teflon-Coated 316L Stainless Steel - Capsule Gasket
Humidity
- 0 to 100 % Relative Humidity - Ambient Humidity
Input Impedance
- 10 kiloohms or more at 2.4 kHz - Communicating Device
Length
- 1.33” (34 mm) - Standard Long Vent
- 4.6” (119 mm) - Total Long Vent
Load
- 0 to 1,290 ohms - for Operation
- 0.22 μF or Less - Load Capacitance
- 250 to 600 ohms - for Digital Communication
- 3.3 MH or Less - Load Inductance
Materials of Construction
- 304 Stainless Steel - Mounting Bracket
- 316 Stainless Steel - Mounting Bracket, Name Plate & Tag & Spacer
- F316 Stainless Steel - Manifold
- SCS 13A - Mounting Bracket
- SCS14A - Mounting Bracket
Mounting
- 2” (50.8 mm) Pipe Mounting Bracket
Mounting Position
- Horizontal
- Vertical
Mounting Position Effect
- Tilting up to 90° will cause Zero Shift up to 0.4 kPa
NACE & NIST
- NACE MR-0103
NPT Connection
- 1/2” NPT Female
Nut & Bolt Material
- 316L Stainless Steel - for Cover Flange, Process Connector & Manifold
- B7 Carbon Steel - for Cover Flange, Process Connector
O-Ring Material
- Buna-N - Cover O-Ring
- Fluororubber - Cover O-Ring
Operating Temperature
- -20° to 80° C (-4° to 176° F)
Orifice Material
- 316 Stainless Steel
Output
- 3.6-21.6 mA
- 4-20 mA DC (2-Wire)
Output Format
- Transistor Output
Overpressure Effect
- ± 0.03 % of URL up to psi: 2,300 (MPa: 16, bar: 160) - for M & H Capsules
- ± 0.06 % of URL - for M & H Capsules
Power Supply Effect
- ± 0.005 % Per Volt (From 21.6 to 32 Vdc, 350 ohms)
Pressure Range
- bar: 0 to 2.1
- kPa: 0 to 210
- mmWC: 0 to 21,000
- psi: 0 to 30.46
Pressure Type
- Absolute
- Differential
- Gauge
Process Connection Material
- ASTM CF-8M
Process Temperature
- -40° to 120° C (-40° to 248° F)
Response Time
- 150 milliseconds - F Capsule
- 90 milliseconds - M & H Capsules
Screw Material
- 316 Stainless Steel
Span - Minimum
- psi: 73 (MPa: 0.5, bar: 5)
Stability
- ± 0.1 % of URL Per 10-Years (All Normal Operating Condition, Including Overpressure Effects) - for M & H Capsules
Static Pressure Effect
- ± 0.02 % of URL Per psi: 1,000 (MPa: 6.9, bar: 69) for M Capsule - Effect on Zero
- ± 0.028 % of URL Per psi: 1,000 (MPa: 6.9, bar: 69) for H Capsule - Effect on Zero
- ± 0.075 % of Span Per psi: 1,000 (MPa: 6.9, bar: 69) for F, M, & H Capsules - Span Effects
- ± 0.1 % of URL Per psi: 1,000 (MPa: 6.9, bar: 69) for F Capsule - Effect on Zero
Supply Pressure - Maximum
- psi: 2,300 (MPa: 16, bar: 160) - for All Capsules
Supply Voltage
- 10.5-30 Vdc - for Intrinsically Safe, Typical N, or Non-Incendive
- 10.5-32 Vdc - for Lightning Protector
- 10.5-42 Vdc - for General Use & Flameproof Typical
- 16.6 Vdc - for Digital Communications, BRAIN & HART
- 24 Vdc, up to 550 ohms Load
Temperature Effect
- ± (0.04 % of Span + 0.009 % of URL) Per 28° C (50° F) for M Capsule - Ambient Temperature Effects
- ± (0.04 % of Span + 0.0125 % of URL) Per 28° C (50° F) for H Capsule - Ambient Temperature Effects
- ± (0.055 % of Span + 0.18 % of URL) Per 28° C (50° F) for F Capsule - Ambient Temperature Effects
Update Time
- 360 milliseconds - Static Pressure
- 45 milliseconds - Differential Pressure
Vibration Effect
- < ± 0.1 % of URL when Tested Per the Requirements of IEC 60770-1 Field with General Application or Pipeline with Low Vibration Level (10-60 Hz 0.15 mm Displacement / 60-500 Hz 2 G) - for Amplifier Housing ASTM CF-8M Stainless Steel
- < 0.1 % of URL when Tested Per the Requirements of IEC 60770-1 Field or Pipeline with High Vibration Level (10-60 Hz, 0.21 mm Displacement / 60-2000 Hz 3 G) - for Amplifier Housing Cast Aluminum Alloy & Cast Aluminum Alloy with Corrosion Resistance Properti
Wetted Materials
- 316L Stainless Steel
- F316L Stainless Steel
Zero Offset
- External Zero is Continuously Adjustable with 0.01 % Incremental Resolution of Span
Documentation
Certificate
Engineering Tools
General Specifications
Manual
- DPharp BRAIN Communication Type pdf 2.7 MB
- Functional Safety Manual pdf 730 KB
- Functional Safety Manual exida Certification pdf 436 KB
- Functional Safety Manual for /SLT pdf 2.6 MB
- Installation Manual - EJX-A Series pdf 7.2 MB
- Manual Change 22-24E: EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters pdf 186 KB
- Manual Change 22-25E: EJX/EJA-E series NEPSI Certification[Option code: /NF2, /NF21, /NS21, /NS24 and /NS25] pdf 312 KB
- Technical Information - Low Flow Transmitters with Integral Flow Orifice pdf 212 KB
- User' Manual - NEPSI Certification pdf 622 KB
- User's Manual - EJX115A Low Flow Transmitter pdf 6.1 MB
- User's Manual - FOUNDATION Fieldbus Protocol pdf 3.7 MB
- User's Manual - HART Protocol pdf 12.2 MB
- User's Mnual - PROFIBUS PA Protocol pdf 6.2 MB