IR400 NDIR Type Infrared Gas Analyzer

Brand: Yokogawa Electric Corporation

The IR400 infrared gas analyzer is capable of measuring the concentrations of NO, SO₂, CO₂, CO, CH₄ and O₂ components in sample gas.

NO, SO₂, CO₂, CO and CH₄ are measured by nondispersive infrared method (NDIR), while O₂ is measured by built-in paramagnetic sensor or external zirconia sensor.

A maximum of 5 components including O₂ (up to 4 components except for CO₂ measurement) are simultaneously measurable.

The mass flow type twin detector of high sensitivity and reliability adopted in the infrared ray method detection unit makes the measurement hardly affected by interfering components.

In addition, the IR400 includes a microprocessor and has a large-size liquid crystal display, providing easy operation, high accuracy and multiple functions.

Optimum as an analyzer unit of measurement system for combustion exhaust gas from refuse incinerator and boiler, or gas from different industrial furnaces.
Features
  • Measure 5 components including O2 simultaneously and continuously
  • Hardly affected by interference from other gases
  • Equipped with abundant functions
  • Large, easy-to-see LCD unit
  • 19 inch rack mount structure

Specifications

Ambient Temperature Range

  • -20° to 60° C (-4° to 140° F) - for Storage Conditions
  • -5° to 45° C (23° to 113° F) - for Operating Conditions

Approvals & Certifications

  • EMC EN 61326-1 Class A, EN 61326-2-3, EN 61000-3-2, EN 61000-3-3
  • RCM EN 61326-1 Class A

BSP Inlet

  • 1/4” BSPT Female

BSP Outlet

  • 1/4” BSPT Female

Cable Length

  • 8.2 feet (2.5 metres) - Power Cable

Communication

  • Half-Duplex Bit Serial
  • Modbus Protocol
  • RS-232C (9-Pins D-sub)
  • RS-485

Consumption

  • 250 VA, Max.

Display

  • 4-Digit LCD with Backlight

Electrical Connectors

  • M3.5 Screw Terminals

Enclosure Finish

  • Gray (Steel-Blue) - Plating
  • Off-White (Munsell 10Y7.5/0.5 or Equivalent) - Front Panel

Enclosure, Body Material

  • Steel - Blue, for Indoor Use

Flow Rate

  • 0.26 gpm (1 LPM) - Purge Gas
  • 0.5 ± 0.25 LPM - Sample Gas

Frequency

  • 50/60 Hz

Humidity

  • 90 % Relative Humidity, Non-Condensing, Max.

Input Signal

  • 0-1 Vdc from an O₂ Sensor Input Section is Non-Isolated - Analog Input Signal

Interface Connection

  • RS-485

Linearity

  • ± 1 % of Full Scale

Load

  • 100 kiloohms Min. for 0-1 Vdc - Permissible Load Resistance
  • 550 ohms, Max.

Materials of Construction

  • 304 Stainless Steel - Gas Inlet/Outlet & Sample Cell
  • Neoprene Rubber - Sample Cell
  • SUS316 - O₂ Sensor Sampling Cell
  • Teflon Tube - Internal Piping
  • Toaron Tube - Internal Piping

Measuring Range

  • 0 to 20 ppm Min., 0 to 100 Vol %, Max.
  • 0 to 200 ppm Min., 0 to 100 Vol %, Max.
  • 0 to 5 Vol % Min., 0 to 25 Vol %, Max.
  • 0 to 50 ppm Min., 0-10 Vol %, Max.
  • 0 to 50 ppm Min., 0 to 100 Vol %, Max.
  • 0 to 50 ppm Min., 0 to 5,000 ppm, Max.
  • Dust: 100 µg/Nm³ or Less in Particle Size of 1 μm or Less

Media

  • Dry Air
  • Gas

Mounting

  • 19” Rack-Mounted with Slide Rail

NPT Inlet

  • 1/4” NPT Female - Gas Inlet

NPT Outlet

  • 1/4” NPT Female - Gas Outlet

Operating Temperature

  • -5° to 45° C (23° to 113° F)

Output

  • 0-1 Vdc, Non-Isolation - Analog Output
  • 100 mA or Less - Transistor Output
  • 4-20 mA DC, Non-Isolation - Analog Output

Power Supply

  • 100-240 Vac - Voltage Rating
  • 85-264 Vac - Allowable Range

Pressure Range

  • psi: 0 to 1.45 (kPa: 0 to 10, bar: 0 to 0.1) or Less (Gas Outlet Side Should be Open to the Atmospheric Air)

Ratio

  • ≤ 1:25 (Except O₂ Analyzer) - Measuring Range Ratio
  • ≤ 1:5 (O₂ Analyzer) - Measuring Range Ratio

Relay Output

  • 250 Vac / 2 A, Resistive Load - Relay Contact Output

Repeatability

  • ± 0.5 % of Full Scale
  • ± 1 % of Full Scale - for Range less than 0-50 ppm

Response Time

  • Approximately 20 seconds (For 90 % Response)
  • Within 60 seconds Including Replacement Time of Sample Gas (For 90 % of Full Scale Response)

Span & Zero Effect

  • ± 1 % of Full Scale/Week - Zero Drift
  • ± 2 % of Full Scale/Day for Range less than 0-50 ppm - Span & Zero Drift
  • ± 2 % of Full Scale/Week - Span Drift
  • ± 2 % of Full Scale/Week for Range Equal to or more than 50 ppm & less than 200 ppm - Zero Drift

Temperature Range

  • 0° to 50° C (32° to 122° F)

Window Material

  • CaF₂ - Infrared Ray Transmitting Window
show more